Position:Home >> Abstract

Mathematics model of RO system with discrete parameters for membrane and pipe  
Authors: Jing Dawei[1],  Li xiaoqing[1],  Su Weiguo[1],  Luo Hao[2],  An Jingbo[3]
Units: 1 Tianjin Institute of Urban Construction , 2 Siemens Water Technologies & Engineering (Tianjin) Co., Ltd , 3 Harbin ROPV Industry Development Center
KeyWords: reverse osmosis membrane system; mathematics model; system simulation; discrete parameters
ClassificationCode:TU991.26+3
year,volume(issue):pagination: 2011,31(2):35-38

Abstract:
The influence of reverse osmosis system operating conditions for discrete element performance parameters and discrete pipeline structure parameters was analyzed. The system mathematics model characterized with the tow kinds of discrete parameters was proposed, and individual paradigm for system analysis was introduced.
Keywords: reverse osmosis membrane system; mathematics model; system simulation; discrete parameters
 

Funds:

AuthorIntro:
靖大为(1954-),男,天津市人,硕士毕业,研究方向:分离膜工艺研究,工作单位:天津城市建设学院膜技术中心,邮箱:david_j5996@sina.com, 电话13902085201

Reference:
[1] 靖大为. 反渗透系统优化设计[M]. 北京:化学工业出版社,2006:94-98
[2] 靖大为,罗浩. 反渗透膜元件及膜系统的数学模型[J]. 工业水处理
2009.29(3):068-071
[3] 伍悦滨,王芳. 工程流体力学(水力学)[M]. 北京:中国建筑工业出版社,2006:52-54

Service:
Download】【Collect

《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com

京公网安备11011302000819号