Position:Home >> Abstract

Comparison between threshold flux and limiting flux during Dongjiang water treatment using ultrafiltration membranes
Authors: Sun Guosheng1, Liu Shuai2, Wu Rui1, YAN Zhongsen3, QU Fangshu2, LIANG Heng2, LI Guibai2
Units: 1. Guangdong Yuehai Water Co.,Ltd., Shenzhen 518021,China; Changping Yuehai Water Co. Ltd., Dongguan, 523570; 3. School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China
KeyWords: Ultrafiltration membrane; threshold flux; Limiting flux
ClassificationCode:TQ028.8
year,volume(issue):pagination: 2016,36(6):126-132

Abstract:
 Membrane flux determines both running stability and capital investment of a water treatment engineering using ultrafiltration. Hence, design flux is one of the most important parameters for an ultrafiltration system. On a basis of membrane technology developments and membrane cost decreasing, lower fluxes can gradually become acceptable in drinking water treatment field. However, although there are various low flux concepts used for membrane fouling control, a clear definition of low flux for ultrafiltration membranes has not been properly developed yet. In this work, the filtration tests of surface water and coagulation-sedimentation effluent were performed under both threshold and limiting fluxes. Both water purification performance and fouling developments were compared. The results indicated that the stable filtration of the tested water samples could be obtained only under the limiting flux (5.0 L/m2h). Hence, the limiting flux could be regarded as a possible resolution for membrane fouling control and stable operation of a ultrafiltration system.

Funds:

AuthorIntro:

Reference:
 [1] 李圭白,瞿芳术. 城市饮水净化超滤水厂设计若干新思路[J]. 给水排水. 2015(01): 1-3.
 [2] Lee N, Amy G, Croué J, et al. Identification and understanding of fouling in low-pressure membrane (MF/UF) filtration by natural organic matter (NOM)[J]. Water Research. 2004, 38(20): 4511-4523.
 [3] Yuan W, Zydney A L. Humic Acid Fouling during Ultrafiltration[J]. Environmental Science & Technology. 2000, 34(23): 5043-5050.
 [4] Field R W, Pearce G K. Critical, sustainable and threshold fluxes for membrane filtration with water industry applications[J]. Advances in Colloid and Interface Science. 2011, 164(1-2): 38-44.
 [5] Field R W, Wu D, Howell J A, et al. Critical flux concept for microfiltration fouling[J]. Journal of Membrane Science. 1995, 100(3): 259-272.
 [6] 王兆之,梁恒,李圭白. 预处理对阈通量的影响[J]. 哈尔滨工业大学学报. 2013, 45(6): 38-42.
 [7] Peter-Varbanets M, Hammes F, Vital M, et al. Stabilization of flux during dead-end ultra-low pressure ultrafiltration[J]. Water Research. 2010, 44(12): 3607-3616.
 [8] Peter-Varbanets M, Zurbrügg C, Swartz C, et al. Decentralized systems for potable water and the potential of membrane technology[J]. Water Research. 2009, 43(2): 245-265.
 [9] Peter-Varbanets M, Gujer W, Pronk W. Intermittent operation of ultra-low pressure ultrafiltration for decentralized drinking water treatment[J]. Water Research. 2012, 46(10): 3272-3282.
[10] Howell J A. Sub-critical flux operation of microfiltration[J]. Journal of Membrane Science. 1995, 107(1-2): 165-171.
[11] Diez V, Ezquerra D, Cabezas J L, et al. A modified method for evaluation of critical flux, fouling rate and in situ determination of resistance and compressibility in MBR under different fouling conditions[J]. Journal of Membrane Science. 2014, 453: 1-11.
[12] van der Marel P, Zwijnenburg A, Kemperman A, et al. An improved flux-step method to determine the critical flux and the critical flux for irreversibility in a membrane bioreactor[J]. Journal of Membrane Science. 2009, 332(1–2): 24-29.
[13] Le Clech P, Jefferson B, Chang I S, et al. Critical flux determination by the flux-step method in a submerged membrane bioreactor[J]. Journal of Membrane Science. 2003, 227(1-2): 81-93.
[14] 董秉直,刘风仙,桂波. 在线混凝处理微污染水源水的中试研究[J]. Industrial Water Treatment. 2008, 01期(1): 40-43.
[15] 袁栋栋,樊耀波,徐国良,等. 膜生物反应器中临界通量理论的研究[J]. 膜科学与技术. 2010(02): 97-103.
[16] Bacchin P, Aimar P, Field R. Critical and sustainable fluxes: Theory, experiments and applications[J]. Journal of Membrane Science. 2006, 281(1-2): 42-69.
[17] Peter-Varbanets M, Margot J, Traber J, et al. Mechanisms of membrane fouling during ultra-low pressure ultrafiltration[J]. Journal of Membrane Science. 2011, 377(1-2): 42-53.
 