含铜废水膜电解实验研究
作者:雷兆武12  陈婧12 王玉玲12  耿世刚12
单位: 1.中国环境管理干部学院环境工程系,河北秦皇岛 066004, 2.富士康科技集团鸿胜科技公司,河北秦皇岛 066004
关键词: 膜电解,含铜废水,废水性质,Cu2+去除
出版年,卷(期):页码: 2012,32(2):96-99

摘要:
采用膜电解技术,对含铜废水和含铜污泥废水进行了废水中Cu2+去除的实验研究。对于含铜废水在以氨水、NaOH、草酸为阴极液电解质时,废水中Cu2+去除率分别为90.1%、50.4%和82%;废水中Cu2+浓度分别为11.75mg/L、55.4mg/L和20.92mg/L。对于含铜污泥废水在以氨水、NaOH、硫化钠为阴极液电解质时,废水中Cu2+去除率分别为20.75%、61.06%和40.28%。膜电解过程能实现废水中Cu2+的去除和回收,但废水组成对膜电解过程的效果有着重要的影响。
Experiment was develpoed to remove Cu2+ from Wastwater and sludge wastwater containning Cu2+ with membrane eletrolysis. When electrolyte in cathode cell was ammonia, NaOH, oxalic acid,  Cu2+  removal ratio was 90.1 percent, 50.4 percent, 82peicent for wastewater containning Cu2+; Cu2+ concentration in wastwater was 11.75mg/L,55.4mg/L and 20.92mg/L. When electrolyte in cathode cell was ammonia, NaOH, sodium sulfide,  Cu2+  removal ratio was 20.75 percent, 61.06 percent, 40.28 percent for sludge wastewater containning Cu2+. Membrane eletrolysis could achieve Cu2+ removal and recycle from Wastwater and sludge wastwater containning Cu2+, but wastewater quality was impotant influence to its result.
雷兆武(1971-),男,江西九江人,硕士,讲师,主要从事废水处理及资源化研究。

参考文献:
1.吴彦军, 张林楠, 李振山,重金属废水无害化处理技术最新进展,工业水处理,2009,29(3);
2. 廖志民 朱小红 杨圣云,电镀废水处理与资源化回用技术发展现状与趋势,环境保护, 2008, 406(10B);
3. 雷兆武,孙颖, 离子交换技术在重金属废水处理中的应用, 环境科学与管理,2008,33(10);
4. 石太宏,  陈 可,电镀重金属污泥的无害化处置和资源化利用,污染防治技术,2007,20(2);
5.张梅玲,蔚东升,等,离子膜电解技术在废水处理中的应用研究进展,工业水处理,2006,26(8)。

服务与反馈:
文章下载】【加入收藏

《膜科学与技术》编辑部 地址:北京市朝阳区北三环东路19号蓝星大厦 邮政编码:100029 电话:010-64426130/64433466 传真:010-80485372邮箱:mkxyjs@163.com

京公网安备11011302000819号