中空纤维超滤膜组件通量分布的数值模拟
作者:庄黎伟,戴干策
单位: 华东理工大学化学工程联合国家重点实验室,上海 200237
关键词: 中空纤维膜组件;超滤;数值模拟;多孔介质模型;通量三维分布
出版年,卷(期):页码: 2016,36(1):86-95

摘要:
 为了研究中空纤维超滤膜组件通量分布,建立了基于膜丝实体为骨架的三维多孔介质模型,通过商用有限体积法软件求解管壳程以及膜丝多孔区纯水渗透过程的控制方程,得到了管壳程的流场信息和多孔区的通量分布。研究表明,任意膜丝和膜丝束均存在通量分布的三维不均匀性,局部高通量增大了设备能耗,降低了组件效率;增大进出口压差降低了通量分布的均匀性,由于考虑了进口效应而更接近实际;膜丝渗透性的提高降低了通量分布的均匀性,在本文研究范围内,相同的进出口压差,膜丝渗透性提高5倍,产水量仅提高10%。本文计算流体力学模型适用于膜丝单元和膜组件研究,与实验偏差均在10%以内,可用于指导组件设计和优化。
 In order to investigate the flux distribution in the hollow fiber membrane module, a three dimensional porous media model was built based on the skeleton of the porous support. The conservation equations of the shell and lumen space and the porous zone were solved by adopting the finite-volume based commercial code to describe the water ultrafiltration process. The flux distribution in the porous zone was obtained as well as the flow field in the shell and lumen space. Conclusions can be drawn from the simulation results: For arbitrary hollow fiber and fiber bundle, three dimensional non-uniformity of the flux distribution existed. The high local flux raised the energy consumption and decreased the efficiency of the module. An increase in the trans-membrane pressure caused a decrease in the uniformity of the flux distribution. Considering the effect of the inlet pattern makes the simulation results more applicable. Decreasing the permeability of the membrane improved the uniformity of the flux distribution. In the scope of this article, with constant trans-membrane pressure, the water flow-rate increased only by 10% when the permeability increased by 500%. The CFD model is suitable for research of single fiber and hollow fiber membrane module. The numerical results agreed well with the experimental data. Therefore, the model contributes to designing and optimizing the module structure.
作者简介: 庄黎伟(1988—),男,江苏丹阳市人,博士研究生,主要从事膜组件结构设计与优化的研究 *通讯作者,E-mail:gcdai@ecust.edu.cn

参考文献:
 [1] Li N N, Fane A G, Ho W W, et al. Advanced membrane technology and applications[M]. Wiley. com, 2011.
 [2] Yang X, Wang R, Fane A G, et al. Membrane module design and dynamic shear-induced techniques to enhance liquid separation by hollow fiber modules: a review[J]. Desalination and Water Treatment. 2013, 51(16-18): 3604-3627.
 [3] Harmant P, Aimar P. Coagulation of colloids retained by porous wall[J]. AIChE journal. 1996, 42(12): 3523-3532.
 [4] Chang S, Fane A G. The effect of fibre diameter on filtration and flux distribution—relevance to submerged hollow fibre modules[J]. Journal of Membrane Science. 2001, 184(2): 221-231.
 [5] Günther J, Schmitz P, Albasi C, et al. A numerical approach to study the impact of packing density on fluid flow distribution in hollow fiber module[J]. Journal of membrane science. 2010, 348(1): 277-286.
 [6] 王捷,张宏伟,贾辉,等. 浸没式中空膜纤维尺寸的优化模拟[J]. 膜科学与技术. 2008, 28(1): 31-34.
 [7] 杨毅,王保国. 中空纤维膜接触器的计算流体力学模拟[J]. 天津工业大学学报. 2008, 27(3): 32-35.
 [8] 杨毅,王保国,彭勇. 中空纤维膜组件壳程流动的数值模拟[J]. 化工学报. 2008, 59(8): 1979-1985.
 [9] Ghidossi R, Veyret D, Moulin P. Computational fluid dynamics applied to membranes: State of the art and opportunities[J]. Chemical Engineering and Processing: Process Intensification. 2006, 45(6): 437-454.
[10] Bessiere Y, Fletcher D F, Bacchin P. Numerical simulation of colloid dead-end filtration: Effect of membrane characteristics and operating conditions on matter accumulation[J]. Journal of Membrane Science. 2008, 313(1): 52-59.
[11] Günther J, Hobbs D, Albasi C, et al. Modeling the effect of packing density on filtration performances in hollow fiber microfiltration module: A spatial study of cake growth[J]. Journal of Membrane Science. 2012, 389(0): 126-136.
[12] Buetehorn S, Volmering D, Vossenkaul K, et al. CFD simulation of single-and multi-phase flows through submerged membrane units with irregular fiber arrangement[J]. Journal of Membrane Science. 2011, 384(1): 184-197.
[13] Wang Y, Brannock M, Cox S, et al. CFD simulations of membrane filtration zone in a submerged hollow fibre membrane bioreactor using a porous media approach[J]. Journal of Membrane Science. 2010, 363(1–2): 57-66.
[14] Serra C, Clifton M J, Moulin P, et al. Dead-end ultrafiltration in hollow fiber modules: Module design and process simulation[J]. Journal of membrane science. 1998, 145(2): 159-172.
[15] Fluent I. FLUENT user’s guide[Z]. Fluent Inc, 2006.
[16] Oberkampf W L, Trucano T G. Verification and validation in computational fluid dynamics[J]. Progress in Aerospace Sciences. 2002, 38(3): 209-272.
[17] Fimbres-Weihs G A, Wiley D E. Review of 3D CFD modeling of flow and mass transfer in narrow spacer-filled channels in membrane modules[J]. Chemical Engineering and Processing: Process Intensification. 2010, 49(7): 759-781.
[18] Costello M J, Fane A G, Hogan P A, et al. The effect of shell side hydrodynamics on the performance of axial flow hollow fibre modules[J]. Journal of Membrane Science. 1993, 80(1): 1-11.
[19] Idelchik I E. Fluid dynamics of industrial equipment-flow distribution design methods[J]. 1992.
[20] Kim J, Digiano F A. Defining critical flux in submerged membranes: influence of length-distributed flux[J]. Journal of membrane science. 2006, 280(1): 752-761.
[21] Yoon S, Lee S, Yeom I. Experimental verification of pressure drop models in hollow fiber membrane[J]. Journal of Membrane Science. 2008, 310(1–2): 7-12.
[22] Li X, Li J, Wang J, et al. Experimental investigation of local flux distribution and fouling behavior in double-end and dead-end submerged hollow fiber membrane modules[J]. Journal of Membrane Science. 2014, 453(0): 18-26.
 

服务与反馈:
文章下载】【加入收藏

《膜科学与技术》编辑部 地址:北京市朝阳区北三环东路19号蓝星大厦 邮政编码:100029 电话:010-64426130/64433466 传真:010-80485372邮箱:mkxyjs@163.com

京公网安备11011302000819号