投加FeCl3改善PAC四级逆流吸附-微滤工艺的膜污染研究
作者:于金山1,李竞2,郭军科1,王丹2,张光辉2,顾平2
单位: 1.国网天津市电力公司电力科学研究院 天津 300384;2.天津大学环境科学与工程学院,天津300072
关键词: 粉末活性炭;二级出水;四级逆流吸附;膜清洗;膜污染
出版年,卷(期):页码: 2016,36(6):108-112

摘要:
 粉末活性炭(PAC)四级逆流吸附-微滤组合工艺处理城镇污水厂二级出水的试验存在着较严重的膜污染现象,处理水量达到172.8 L时,膜比通量(SF)急剧下降79.59%。对试验结束后的膜进行分析,滤饼层阻力占总膜阻力的70.3%, PAC及原水中悬浮物形成的滤饼层污染是SF迅速下降的主要原因。为了解决膜堵塞问题,向反应器中投加一定浓度的FeCl3。结果表明:加入10~20 mg/LFeCl3后,处理水量大于300 L,SF仍维持在20 L/(m2•h•mH2O)以上, SF下降缓慢,反应器能够稳定运行。另外,FeCl3的投加对有机物的去除有积极作用,组合工艺中出水DOC浓度均有小幅度的降低。
 The experiment on hybrid process of PAC four-stage countercurrent adsorption and microfiltration for treating municipal secondary effluent existed serious membrane fouling phenomenon. When the secondary effluent with a volume of 172.8 L was treated, membrane specific flux (SF) fell by 79.59%. The membrane was analyzed after the experiment, filter cake layer resistance was 70.3% of the total membrane resistance. The filter cake layer formed by PAC and suspended solids in the secondary effluent was the main cause of SF declining rapidly. In order to solve the membrane fouling problem, a certain concentration of FeCl3 was dosed into the reactor. The experiment results indicated that when dosing 10-20 mg/L of FeCl3 and treating more than 300 L of water, SF maintained at more than 20 L/ (m2•h•mH2O), SF decreased slowly, the reactor could be operated steadily. In addition, it has positive effect on the removal of organics when dosing FeCl3, concentration of DOC in the effluent reduced slightly.
第一作者简介:于金山(1979-),男,吉林省松原市人,工程师,从事环境与水处理研究,E-mail:pinfan10@126.com. *通讯作者:E-mail:pinfan10@126.com.

参考文献:
 [1]  Chunxia Zhao, Ping Gu, Hangyu Cui, Guanghui Zhang. Reverse osmosis concentrate treatment via a PAC-MF accumulative countercurrent adsorption process[J]. Water Research, 2012, 46(1):218-226.
[2]  Xiaozhu Wei, Ping Gu, Guanghui Zhang. Reverse osmosis concentrate treatment by a PAC four-stage countercurrent adsorption/MF hybrid process [J]. Desalination, 2014, 352(3): 18-26.
[3]  李  竞, PAC四级逆流吸附-微滤组合工艺处理二级出水的试验研究[D]. 天津: 天津大学环境科学与工程学院, 2015. 
[4]  Ling-Ling Zhang, Dong Yang, Zi-Jie Zhong, Ping Gu. Application of hybrid coagulation-microfiltration process for treatment of membrane backwash water from waterworks[J]. Separation and Purification Technology, 2008, 62(2): 415-422.
[5]  Shimizu Y, Okuno Y I, Uryu K, et al. Filtration characteristics of hollow fiber microfiltration membranes used in membrane bioreactor for domestic wastewater treatment[J]. Water Research, 1996, 30(10): 2385-2392.
[6]  周  丹, 中空纤维膜生物反应器的试验研究及阻力特性分析[D]. 天津: 天津大学环境科学与工程学院, 1998.
[7]  Shimizu Y, Rokudai M, Tohya S, et al. Effect of membrane resistance on filtration characteristics for methanogenic waste[J]. Kagaku Kogaku Ronbunshu, 1990, 16(1): 145-151.
[8]  Hodgson P H, Leslie G L, Fane A G, et al. Cake resistance and solute rejection in bacterial microfiltration: the role of the extracellular matrix[J]. Journal of Membrane Science, 1993, 79(1): 35-53.
[9]  Wang W, Gu P, Zhang G, et al. Organics removal from ROC by PAC accumulative countercurrent two-stage adsorption-MF hybrid process–A laboratory-scale study[J]. Separation and Purification Technology, 2013, 118: 342-349. 
[10] 郑影奇, 舒生辉. 絮凝剂在水处理中的应用现状和发展前景[J]. 广西轻工业, 2011(2): 87-88. 
[11] 周玲玲, 张永吉, 孙丽华, 等. 铁盐和铝盐混凝对水中天然有机物的去除特性研究[J]. 环境科学, 2008, 29(5): 1187-1191. 
[12] 韦晓竹. 反渗透浓水中有机物的分析及去除研究[D]. 天津: 天津大学环境科学与工程学院, 2014.

服务与反馈:
文章下载】【加入收藏

《膜科学与技术》编辑部 地址:北京市朝阳区北三环东路19号蓝星大厦 邮政编码:100029 电话:010-64426130/64433466 传真:010-80485372邮箱:mkxyjs@163.com

京公网安备11011302000819号