长流程反渗透系统的有机、无机及络合污染分析
作者:杨小奇  靖大为
单位: 天津城市建设学院膜技术研究中心,天津,300384
关键词: 反渗透系统;有机物污染;无机物污染;络合物污染
出版年,卷(期):页码: 2012,32(4):50-53

摘要:
通过对长流程反渗透工艺系统在线监测的运行试验分析,比较了有机、无机及络合污染对应系统给水压力、透盐率、膜压降及膜通量等参数的变化规律,明确了硫酸钙污染与腐殖酸污染对于膜系统运行参数的影响,特别是指出了腐殖酸与钙离子构成的络合污染对于系统的危害。
Through the analysis of online monitoring running test on a long process reverse osmosis system, the variations of the membrane parameters such as feed water pressure, salt permeability, pressure drop and membrane flux in organic, inorganic and complex pollution were compared.The influence of membrane system operating parameters by calcium sulfate pollution and humic acid pollution were defined, system damage caused by the composition of humic acid complexation with calcium ions were pointed out in particular.
杨小奇(1985-),男,河北邯郸人,硕士研究生,研究方向为膜法水处理

参考文献:
[1]靖大为. 反渗透系统优化设计[M] . 北京:化学工业出版社,2006:27~28.
[2] Leppard G G,Mavrocordatos D,Perret D. Electron-optical charac-terization of nano-and micro-particles in raw and treated waters:anoverview[J] .Water Science and Technology, 2004, 50 (12) :1-8 .
[3] Tang C Y,Kwon YN,Leckie J O. Fouling of reverse osmosis andnanofiltration membranes by humic acid-effects of solutioncomposition and hydrodynamic conditions[J] .Journal of Membrane Science, 2007, 290 (1-2) :86—94 .
[4] 刘家祺.分离过程与技术[M].天津:天津大学出版社,2001:90-92.
   