浸没式超滤膜组件运行参数的优化
作者:朱圆圆1,沈菊李2,吕晓龙1,左滢1,颜婷婷2,眭彤2
单位: 天津工业大学 生物化工研究所,天津 300387;2.杭州水处理技术研究开发中心有限公司,浙江 杭州 310012
关键词: 浸没式超滤;正交试验;工艺参数
出版年,卷(期):页码: 2014,34(6):106-111

摘要:
曝气量、抽停比、膜通量、反洗水量等工艺参数是影响浸没式超滤膜污染的主要因素,本研究采用正交试验的方法对这些因素的影响显著性进行分析,从方差分析的结果可得曝气量和抽停比对膜污染具有极为显著地影响作用,反洗水量对膜污染具有显著影响,所设定的膜通量对膜污染无显著影响。通过因素水平表对工艺参数进行优化,最终优化得到的工艺参数为,曝气量为4 Nm3/h ,抽停比为16 min/2 min,反洗水量为产水量的80 %,膜通量为55 LMH。膜组件在最优的条件下可以稳定运行3-4 d,之后需要进行在线化学清洗。
The factors of aeration rate , on/off ratio, backflushing flow and membrane flux had important roles on the fouling of submerged ultrafiltration membrane. Orthogonal experiment was used to find out the remarkable influence function among these factors, the results of the variance analysis showed that the factors of aeration rate and on/off ratio had a significant influence on membrane fouling, and the factor of backflushing flow had a slight influence, while the factor of membrane flux had no influence on the membrane fouling. The obtained optimal parameters were; aeration rate 4 Nm3/h;on/ off ratio 16 min/2 min,;backflushing flow which is 80 % of water yield and membrane flux 55 LMH. The module can run steadily in the optimum condition for 3-4 days before chemical cleaning.
朱圆圆(1987— ),女,河南,研究生,研究方向为膜法水处理技术,E-mail:zyy0215peace@163.com 通讯作者:吕晓龙,教授

参考文献:
[1]杨宗政,顾平.膜生物反应器运行中的膜污染及其控制[J].膜科学与技术,2005,25(2):80-84.
[2]张国俊,刘忠洲.膜过程中超滤膜污染机制的研究及其防治技术进展[J].膜科学与技术,2001,21(4):39-45.
[3]曹国凭,马浩,关会玲.超滤技术在地表水处理中的应用和研究进展[J].工业水处理,2009,29:(2):6-9.
[4]孙丽华,李星,杨艳玲.浸没式超滤膜运行中膜污染控制方法试验研究[J],哈尔滨商业大学学报(自然科学版),2009,25(6):664-668.
[5]H.Y.Ng,T.W.Tan,S.L.Ong.Membrane fouling of submerged membrane bioreactors:impact of mean cell residence time and the contributing factors[J].Environment Science and Technology,2006,40(8):2706-2713.
[6]Y.Lu,Z.W.Ding,L.Y.Liu,et al.The influence of bubble characteristics on the performance of submerged hollow fiber membrane module used in microfiltration[J].Separation and Purification Technology,2008,61(1):89-95.
[7]齐鲁,李圭白,程荣.运行条件对浸没式超滤处理地表水膜污染的影响[J].给水排水动态,2010,12:9-10.
[8]何攀,何凤华,王海燕.操作条件对浸没式超滤膜污染影响的中试研究[J].给水排水,2010,26(3):12-17.
[9]徐仲安,王天保,李常英等.正交试验设计方法简介[J],科技情报开发与经济,2002,12(5):148-150.
[10]董如何,肖必华,方永水.正交试验的理论设计方法及应用[J].安徽建筑工业学院学报(自然科学版),2004,12(6):103-106.
[11]R.W.Field,D.Wu,J.A.Howell,et al.Critical flux concept for microfiltration fouling [J].J.Membr.Sci,1995,100(3):259-272.
[12]B.D.Cho,A.G.Fane.Fouling transients in nominally sub-critical flux operation of a membrane bioreactor[J].J.Membr.Sci,2002,209(2):391-403.
[13]郑祥,樊耀波.膜生物反应器运行条件的优化及膜污染的控制[J].给水排水,2001,27(4):41-44.
[14]杨小丽,王世和,卢宁.一体式 MBR 控制膜污染的最佳曝气强度及影响因素[J].水处理技术,2006,32(5):12-16.
[15]金丕焕.医用统计方法学[M].上海:上海医科大学出版社,1995,89.
[16]孙友峰,刘锐,黄霞.一体式膜-生物反应器中膜面污泥沉积速率及其影响因素[J].环境科学,2002,23,26-30.
[17]D.Y.Kwon,S.Vigneswaran,A.G.Fane,et al.Experimental determination of critical flux in cross-flow microfiltration[J].Separation and Purification Technology,2000,19(3):169-181.
[18]张伟.适用微污染水源水的农村饮水浸没式超滤组合工艺研究[D].博士学位论文,清华大学,2011,45-46.
[19]吕晓龙.连续微滤技术研究[J].膜科学与技术,2003,23(4):19-24.
 

服务与反馈:
文章下载】【加入收藏

《膜科学与技术》编辑部 地址:北京市朝阳区北三环东路19号蓝星大厦 邮政编码:100029 电话:010-64426130/64433466 传真:010-80485372邮箱:mkxyjs@163.com

京公网安备11011302000819号