Abstract:
The effect of polyvinylidene fluoride (PVDF) hollow fiber membrane module parameters (ratio of height to diameter, the packing fraction) for  on vacuum membrane distillation (VMD) performance for desalinizing concentrated seawater  was studied in this work. VMD performances were developed using the ratio of height to diameter of 25:2, 15:1,35:2, 20:1, 45:2 and the packing fraction of 1%, 5%, 10% membrane modules in the experiment, at the same time VMD performances were developed using the ratio of height to diameter of 10:3, 70:9,10:1 and the packing fraction of 7.11%, 9.48%, 14.22% membrane modules in pilot test. The results showed that VMD flux increased with increasing the ratio of height to diameter or decreasing the packing fraction. The rejection of vacuum membrane distillation production was higher than 99.9% during this process.

Funds:

AuthorIntro:
唐 娜(1972-),女,辽宁海城市人,博士,教授,博士研究生导师。主要研究方向:膜分离、海卤水资源综合利用.(tjtangna@tust.edu.cn)

Reference:
[1]Khayt M, Godino P, Mengual J I. Nature of flow on sweeping gas membrane distillation [J]. Journal of Membrane Science,2000,170(2):243-255.
[2]Lawson K W, Lloyd D R. Membrane distillation. Module design and performance evaluation using vacuum membrane distillation[J]. Journal of Membrane Science.1996,120:111-121.
[3]环国兰,杜启云,王薇.膜蒸馏技术研究现状[J].天津工业大学学报,2009,28 (4):12-18.
[4]Izquierdo GMA, Garcia P M C, Fernandez P C. Air gap membrane distillation of sucrose aqueous solutions[J]. Journal of Membrane Science.1999, 155:291-307.
[5]吴庸烈.膜蒸馏技术及其应用进展[J].膜科学与技术,2003,23(4):67-79.
[6]王许云, 张林, 陈欢林.膜蒸馏技术最新研究现状及进展[J].化工进展, 2007, 26(2):168-172.
[7]吴刚,武春瑞,吕晓龙.聚偏氟乙烯中空纤维膜蒸馏性能研究[J].水处理技术2008,34(5):20-24.
[8]Termpiyakul P, Jiraratananon R, Srisurichan S. Heat and mass transfer characteristics of a direct contact membrane[J].Desalination,2005,177:133-141.
[9]Guijt C M, Racz I G, Reith T. Membrane fouling during the treatment of textile waste water by membranes[J]. Desalination,2000, 132:255-261.
[10]阎建民,马润宇.用于膜蒸馏的中空纤维膜组件优化[J].化工学报.2000, 51 (6):827-831.

Service:
Download】【Collect

《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com

京公网安备11011302000819号