Pilot studies on treating Titanium dioxide wastewater by Ultrafiltration+Reverse osmosis technology |
Authors: LIU Zuhu1,LIu Yongzhu1, CHEN Jian 2, MI Ren 3 |
Units: 1.Nanjing KUMHO GPRO Chemical Co.,Ltd, Nanjing 210047; 2. Jiangsu Kaimi membrane technology Co.,Ltd, Nanjing 210049; 3. Nanjing Titanium dioxide Chemical Co.,Ltd, Nanjing 210047 |
KeyWords: Titanium dioxide wastewater; Ultrafiltration; Reverse osmosis |
ClassificationCode: |
year,volume(issue):pagination: 2014,34(2):77-80 |
Abstract: |
Through the pilot study on treating Titanium dioxide wastewater by Ultrafiltration+Reverse osmosis technology, reviewed the flux,water production time and drain cycle of Ultrafiltration is 38.8LMH, 22min and 22, turbidity of production water less than 0.2NTU, water recovery is about 92%. Flux of reverse osmosis is 15LMH, water recovery is about 60%~65%, clean cycle is about 22~28day. The parameter optimization of Ultrafiltration+Reverse osmosis is received. |
Funds: |
AuthorIntro: |
刘祖虎(1986-),山东临清人,工学硕士,工程师,2010年毕业于天津大学化学工艺系,主要研究方向为化工系统优化及节水节能。 |
Reference: |
[1]KOCH公司中空纤维超滤技术手册,2009 [2]KOCH公司Fluid System反渗透/纳滤膜产水技术手册,2009 [3]反渗透和纳滤膜元件产品与技术手册,陶氏水处理及过程解决方案,2012 |
Service: |
【Download】【Collect】 |
《膜科学与技术》编辑部 Address: Bluestar building, 19 east beisanhuan road, chaoyang district, Beijing; 100029 Postal code; Telephone:010-80492417/010-80485372; Fax:010-80485372 ; Email:mkxyjs@163.com
京公网安备11011302000819号